Nuevo León, Mexico
Laguna Seca Corridor
Gas transmission right-of-way, 12 km. Nine anomalies including two third-party encroachments.
248
ha
Area covered
84
min
Flight time
9
flagged
Anomalies found
52
°C
Hottest reading
Findings
Compressor discharge line at 52.1 °C above design
Two unauthorised vehicle crossings on the right-of-way
Six cathodic-protection test posts damaged
Debrief
The daylight frames were used for encroachment, the IR frames for process heat; both came from one pass.
Encroachments were routed to the land team, process findings to operations.
One flight now covers the line walker’s route and the thermography contractor’s.
Alejandro Garza, ROW coordinator
Next contact